Seitenansicht 27
Functional Description
Page 13 AM4311 User Guide
C3h OEM Kontron
IPMI-L Link
6Fh Standard
IPMI sensor spe-
cific
02h
03h
IPMB-L Disable
Event Data 2: always 0
Event Data 3:
bit[7:3]: always 0
bit [2:0]:
0h = no failure
1h = Unable to drive clock HI
2h = Unable to drive data HI
3h = Unable to drive clock LO
4h = Unable to drive data LO
5h = clock low timeout
6h = Under test (the IPM Controller is attempting
to determine who is causing a bus hang)
7h = Undiagnosed Communication Failure
IPMB-L Enable
Event Data 2: always 0
Event Data 3:
bit[7:3]: always 0
bit [2:0]:
0h = no failure
1h = Unable to drive clock HI
2h = Unable to drive data HI
3h = Unable to drive clock LO
4h = Unable to drive data LO
5h = clock low timeout
6h = Under test (the IPM Controller is attempting
to determine who is causing a bus hang)
7h = Undiagnosed Communication Failure
Table 2-4: OEM Sensor List AM4311 (Continued)
Sensor Type
Event/Reading
type Code
Sensor Specific
Offset
Event Trigger