3.6 Environmental Specifications
3.6.1 Temperature
3.6.2 Operating: (with Kontron heat spreader plate assembly):
» Ambient temperature: 0 to 60°C with an active fan heat sink.
» Non-operating: -30 to +85°C
NOTE: The maximum operating temperature with the heat spreader plate installed is the maximum measurable
temperature on any spot on the heat spreader surface. You must maintain the temperature according to the
specification above.
3.6.3 Operating:
» Maximum operating temperature: 0-60°C
» Non operating: -30°C to +85°C
NOTE: The maximum operating temperature is the maximum measurable temperature on any spot on the module
surface. You must maintain the temperature according to the specification above.
3.6.4 Humidity
» Operating: 10% to 90%, non-condensing
» Non operating: 5% to 95%, non-condensing
3.7 MTBF
TBD