AT8402 Diagnostics running on the Carrier
Page 2 - 5 AT8402 CLI Reference Manual
Description
This test will verify the BCM internal memory banks.
Failure impact
• BCM-00010004 diagnostic code results of failure of one or more BCM internal
memories. The impact is complete loss of Ethernet functionality.
• BCM-00010005 diagnostic code results of failure loading the BCM drivers
BCM shell test
U/A/S|Test| Test |Loop | Run |Pass |Fail | Arguments
| # | Name |Count|Count|Count|Count|
-----+----+-----------------------------+-----+-----+-----+----------
| 50| Memory Fill/Verify | 1| 129| 129| 0| (none)
U/A/S|Test| Test |Loop | Run |Pass |Fail | Arguments
| # | Name |Count|Count|Count|Count|
-----+----+-----------------------+-----+-----+-----+-----+-----------
| 51|Memory Random Addr/Data| 1| 129| 129| 0| (none)
U/A/S|Test| Test |Loop | Run |Pass |Fail | Arguments
| # | Name |Count|Count|Count|Count|
-----+----+-----------------------+-----+-----+-----+-----+----------
| 52|Rand Mem Addr,write all| 1| 129| 129| 0| (none)
2.2.5 BCM_LOOPBACK
Internal loopback test.
Test group: Diagnostics
Test case: bcm
Test procedure: BCM_LOOPBACK
Test host: Carrier
Test IC: quickturn
Test mode: normal
Diagnostic code: BCM-00010005, BCM-00010101 - BCM-00010114
Description
The Ethernet interfaces are tested by establising an PHY loopback internal to the
Ethernet PHYs. It will send test patterns and check correct reception of the test-patterns
for each Ethernet interface. The loopback is either through the BCM internal SERDES
PHY for SERDES based links or through the external 1000BaseT PHY.
Diagnostic codes
BCM-00010101 PHY 1 failed
BCM-00010102 PHY 2 failed
BCM-00010103 PHY 3 failed
BCM-00010104 PHY 4 failed