Chapter 4 Programming PB-TIM2 User’s Manual
4.2.9 Common Control Register
Write Only Register
Address $61
Bit 7
6 5 4 3 2 1 0
Function PWM 1 T IN 2 ST2 ST1 ST0
After Reset 0 0 0 0 0
Where • STx : Authorizes common clear function on corresponding channel
• T IN 2 : Defines the operation of timer channel 2. A 1 in this location will link the
output of channel 0 to the counter clock of channel 2 (channel 0 and 2 will
also be cascaded)
• PWM 1 : Defines the operation of channel 1. A 1 in this location will internally link the
output of channel 0 to the (A) input of channel 1 and the output of channel 1 to the
(A) input of channel 0. With this configuration, both channels generate half a Pulse
Width Modulation signal
4.2.10 Common Interrupt Pending Register
Read Only Register
Address $65
Bit 7
6 5 4 3 2 1 0
Function CH 2 CH 1 CH 0
After Reset 0 0 0
Where CH x : A 1 in this position means an interrupt pending from the corresponding channel
Note : If an interrupt is pending from a given channel then the only way to clear it is to use the channel interrupt clear
register.
Page 4-6 © 1996 PEP Modular Computers July 30, 1997