Kontron VMP1 with Netbootloader Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Kontron VMP1 with Netbootloader herunter. Kontron VMP1 with Netbootloader User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Power PC-based CPU Board

VMP1Power PC-based CPU Boardfor VME ApplicationsManual ID 26037, Rev. Index 01Aug 02The product described in this manual isin compliance with all appl

Seite 2

Preface VMP1Revision HistoryThis document contains information proprietary to PEP Modular Computers. It may not becopied or transmitted by any means,

Seite 3 - Table of Contents

VMP1 VMP1-IO1 Module (Optional)ID 26037, Rev. 01Page A - 4 ® 2002 PEP Modular Computers GmbHB Board InterfacesPCI Expansion ConnectorThe PCI expansion

Seite 4 - Preface VMP1

VMP1 VMP1-IO1 Module (Optional)ID 26037, Rev. 01 Page A - 5® 2002 PEP Modular Computers GmbHC Board LayoutThe VMP1-IO1 has two onboard connectors (CON

Seite 5 - VMP1 Preface

VMP1 VMP1-IO1 Module (Optional)ID 26037, Rev. 01Page A - 6 ® 2002 PEP Modular Computers GmbHD VMP1-IO1 Front Panel Figure A-2: VMP1-IO1 Front PanelThe

Seite 6

VMP1 VMP1-IO1 Module (Optional)ID 26037, Rev. 01 Page A - 7® 2002 PEP Modular Computers GmbHE Technical SpecificationsTable A-1: VMP1-IO1 Specificatio

Seite 7

VMP1 VMP1-IO1 Module (Optional)ID 26037, Rev. 01Page A - 8 ® 2002 PEP Modular Computers GmbHF Board InstallationIn order to keep the installation proc

Seite 8 - Table Number and Title

VMP1 VMP1-IO1 Module (Optional)ID 26037, Rev. 01 Page A - 9® 2002 PEP Modular Computers GmbH Figure A-3: Installation Diagrams 21VMP1-IO1 Front PanelP

Seite 9

VMP1 VMP1-IO1 Module (Optional)ID 26037, Rev. 01Page A - 10 ® 2002 PEP Modular Computers GmbHGPinoutsG1 Jn1 (CON4) Pin AssignmentTable A-2: Jn1, 32-bi

Seite 10 - Trademarks

VMP1 VMP1-IO1 Module (Optional)ID 26037, Rev. 01 Page A - 11® 2002 PEP Modular Computers GmbHG2 Jn2 (CON5) Pin AssignmentTable A-3: Jn2, 32-bit PCIPin

Seite 11 - PrefaceVMP1

VMP1 VMP1-IO1 Module (Optional)ID 26037, Rev. 01Page A - 12 ® 2002 PEP Modular Computers GmbHHJumper SettingThe jumper settings of the IO1 module depe

Seite 12 - For your safety

VMP1ID 26037, Rev. 01VMP1-Post (Optional)Page B - 1® 2002 PEP Modular Computers GmbHVMP1-Post (Optional)VMP1-Post ...

Seite 13

PrefaceVMP1ID 26037, Rev. 01 Page 0 - 11® 2002 PEP Modular Computers GmbHExplanation of Symbols CE ConformityThis symbol indicates that the p

Seite 14 - Two Year Warranty

® 2002 PEP Modular Computers GmbHThis page was intentionally left blank.

Seite 15 - Introduction

VMP1 VMP1-Post (Optional)ID 26037, Rev. 01 Page B - 3® 2002 PEP Modular Computers GmbHVMP1-Post (Optional)Board descriptionThe VMP1-Post is an optiona

Seite 16

® 2002 PEP Modular Computers GmbHThis page was intentionally left blank.

Seite 17 - 1. Introduction

VMP1ID 26037, Rev. 01Optoisolation RS485 Module (Optional)Page C - 1® 2002 PEP Modular Computers GmbHOptoisolation RS485 Module (Optional)Optoisolatio

Seite 18 - VMP1 Introduction

® 2002 PEP Modular Computers GmbHThis page was intentionally left blank.

Seite 19

VMP1 Optoisolation RS485 Module (Optional)ID 26037, Rev. 01 Page C - 3® 2002 PEP Modular Computers GmbHOptoisolation RS485 Module (Optional)Board desc

Seite 20

® 2002 PEP Modular Computers GmbHThis page was intentionally left blank.

Seite 21

JTAG SubsystemID 26037, Rev. 01VMP1Page D - 1® 2002 PEP Modular Computers GmbHJTAG SubsystemJTAG Chain ...

Seite 22

® 2002 PEP Modular Computers GmbHThis page was intentionally left blank.

Seite 23 - Functional Description

VMP1 JTAG SubsystemID 26037, Rev. 01 Page D - 3® 2002 PEP Modular Computers GmbHJTAG SubsystemDescriptionAll the JTAG capable devices on the VMP1 can

Seite 24

VMP1PrefaceFor your safetyYour new PEP product has been developed and carefully tested in order to provide all the fea-tures necessary to ensure full

Seite 25 - 2. Functional Description

VMP1 JTAG SubsystemID 26037, Rev. 01Page D - 4 ® 2002 PEP Modular Computers GmbHIf EMULATOR access to the MPC8240 is required it must be ensured that

Seite 26 - VMP1 Functional Description

PrefaceVMP1General Instructions on UsageIn order to maintain PEP’s product warranty, this product must not be altered or modi-fied in any way. Change

Seite 27

VMP1PrefaceTwo Year WarrantyPEP Modular Computers grants the original purchaser of a PEP product a TWO YEAR LIMITEDHARDWARE WARRANTY as described in t

Seite 28

VMP1ID 26037, Rev. 01IntroductionPage 1 - 1® 2002 PEP Modular Computers GmbHIntroduction1.11.2 Board Introduction ...

Seite 29

® 2002 PEP Modular Computers GmbHThis page was intentionally left blank.

Seite 30

VMP1 IntroductionID 26037, Rev. 01 Page 1 - 3® 2002 PEP Modular Computers GmbH1. IntroductionThe VMP1 is a comprehensive computing platform which brin

Seite 31

VMP1 IntroductionID 26037, Rev. 01Page 1 - 4 ® 2002 PEP Modular Computers GmbH1.1 Board IntroductionThe VMP1 is a VME PowerPC-based single-board compu

Seite 32

VMP1 IntroductionID 26037, Rev. 01 Page 1 - 5® 2002 PEP Modular Computers GmbH1.2 Board OverviewThe VMP1 is a 3U VME CPU board featuring a powerful CP

Seite 33

® 2002 PEP Modular Computers GmbHThis page was intentionally left blank.

Seite 34

VMP1 IntroductionID 26037, Rev. 01Page 1 - 6 ® 2002 PEP Modular Computers GmbH1.3 VMP1 Main SpecificationsTable 1-1: VMP1 Main SpecificationsVMP1 Spec

Seite 35

VMP1 IntroductionID 26037, Rev. 01 Page 1 - 7® 2002 PEP Modular Computers GmbHDebug InterfaceJTAG/BDM VME Connector96-pin VME connectorOnboard Connect

Seite 36

VMP1 IntroductionID 26037, Rev. 01Page 1 - 8 ® 2002 PEP Modular Computers GmbH1.4 Applied Standards1.4.1 CE ComplianceThe PEP Modular Computers’ VME s

Seite 37

VMP1ID 26037, Rev. 01Functional DescriptionPage 2 - 1® 2002 PEP Modular Computers GmbHFunctional Description2.1 Functional Block Diagram ...

Seite 38

VMP1ID 26037, Rev. 01Functional DescriptionPage 2 - 2® 2002 PEP Modular Computers GmbHFunctional Description2.5.2 RTC (STC M41T56) ...

Seite 39

VMP1 Functional DescriptionID 26037, Rev. 01 Page 2 - 3® 2002 PEP Modular Computers GmbH2. Functional Description2.1 Functional Block Diagram Figure 2

Seite 40

VMP1 Functional DescriptionID 26037, Rev. 01Page 2 - 4 ® 2002 PEP Modular Computers GmbH2.2 Front Panels Figure 2-2: Front PanelsStandard VMP1 andVMP1

Seite 41

VMP1 Functional DescriptionID 26037, Rev. 01 Page 2 - 5® 2002 PEP Modular Computers GmbH2.3 Board Layout Figure 2-3: VMP1 Board (Front View) Figure 2-

Seite 42

VMP1 Functional DescriptionID 26037, Rev. 01Page 2 - 6 ® 2002 PEP Modular Computers GmbH2.4 Main FeaturesThe following descriptions provide an overvie

Seite 43 - Installation

VMP1 Functional DescriptionID 26037, Rev. 01 Page 2 - 7® 2002 PEP Modular Computers GmbH PCI agent mode capability • Address translation unit • Intern

Seite 44

VMP1 PrefaceID 26037, Rev. 01 Page 0 - 3® 2002 PEP Modular Computers GmbHTable of ContentsPrefaceManual Table of Contents...

Seite 45 - 3. Installation

VMP1 Functional DescriptionID 26037, Rev. 01Page 2 - 8 ® 2002 PEP Modular Computers GmbH2.4.2 Memory2.4.2.1 System Memory (DRAM)The main memory of the

Seite 46 - VMP1 Installation

VMP1 Functional DescriptionID 26037, Rev. 01 Page 2 - 9® 2002 PEP Modular Computers GmbH2.4.3 Board Interfaces2.4.3.1 VME Interface and PinoutThe VME

Seite 47 - Configuration

VMP1 Functional DescriptionID 26037, Rev. 01Page 2 - 10 ® 2002 PEP Modular Computers GmbHVME Bus Connector PinoutTable 2-1: Pin Assignment J1/P1 VMEPi

Seite 48

VMP1 Functional DescriptionID 26037, Rev. 01 Page 2 - 11® 2002 PEP Modular Computers GmbH2.4.3.2 Ethernet Connector and PinoutThe Ethernet interface i

Seite 49 - 4. Configuration

VMP1 Functional DescriptionID 26037, Rev. 01Page 2 - 12 ® 2002 PEP Modular Computers GmbH2.4.3.3 Serial Interfaces and PinoutsTwo serial ports (RS232)

Seite 50 - VMP1 Configuration

VMP1 Functional DescriptionID 26037, Rev. 01 Page 2 - 13® 2002 PEP Modular Computers GmbH2.4.3.4 PCI Expansion Connector and Pinout Figure 2-5: PCI Ex

Seite 51

VMP1 Functional DescriptionID 26037, Rev. 01Page 2 - 14 ® 2002 PEP Modular Computers GmbHPCI Expansion Connector (CON11) PinoutTable 2-4: PCI Expansio

Seite 52

VMP1 Functional DescriptionID 26037, Rev. 01 Page 2 - 15® 2002 PEP Modular Computers GmbHPERR# 67 68+5V 3)SERR# 69 70GND 1)+5V 3)71 72 PARC/BE1# 73 74

Seite 53

VMP1 Functional DescriptionID 26037, Rev. 01Page 2 - 16 ® 2002 PEP Modular Computers GmbH2.4.3.5 Serial Interface Expansion Connector and PinoutThe se

Seite 54

VMP1 Functional DescriptionID 26037, Rev. 01 Page 2 - 17® 2002 PEP Modular Computers GmbH2.4.3.7 DEBUG Interface and PinoutA JTAG/BDM interface is pro

Seite 55

Preface VMP1ID 26037, Rev. 01Page 0 - 4 ® 2002 PEP Modular Computers GmbHChapter2Functional Description...

Seite 56

VMP1 Functional DescriptionID 26037, Rev. 01Page 2 - 18 ® 2002 PEP Modular Computers GmbH2.5 Special Board Features2.5.1 Watchdog TimerA watchdog time

Seite 57

VMP1 Functional DescriptionID 26037, Rev. 01 Page 2 - 19® 2002 PEP Modular Computers GmbH2.5.4 Front Panel LED’sThree LED’s with the colors red, green

Seite 58

® 2002 PEP Modular Computers GmbHThis page was intentionally left blank.

Seite 59

VMP1ID 26037, Rev. 01InstallationPage 3 - 1® 2002 PEP Modular Computers GmbHInstallation3.1 Board Installation ...

Seite 60

® 2002 PEP Modular Computers GmbHThis page was intentionally left blank.

Seite 61

VMP1 InstallationID 26037, Rev. 01 Page 3 - 3® 2002 PEP Modular Computers GmbH3. InstallationThe VMP1 has been designed for easy installation. However

Seite 62

VMP1 InstallationID 26037, Rev. 01Page 3 - 4 ® 2002 PEP Modular Computers GmbH3.1.1 Front Panel I/O ConnectorsESD Equipment!Your VMP1 board contains e

Seite 63

VMP1ID 26037, Rev. 01ConfigurationPage 4 - 1® 2002 PEP Modular Computers GmbHConfiguration4.1 Jumper Settings ...

Seite 64

VMP1ID 26037, Rev. 01ConfigurationPage 4 - 2® 2002 PEP Modular Computers GmbHConfiguration4.3.4.9 Control Register ...

Seite 65

VMP1 ConfigurationID 26037, Rev. 01 Page 4 - 3® 2002 PEP Modular Computers GmbH4. Configuration4.1 Jumper SettingsPlease see Figures 2-3 and 2-4 in Ch

Seite 66

VMP1 PrefaceID 26037, Rev. 01 Page 0 - 5® 2002 PEP Modular Computers GmbHChapter3Installation...

Seite 67 - NetBootLoader

VMP1 ConfigurationID 26037, Rev. 01Page 4 - 4 ® 2002 PEP Modular Computers GmbH4.1.3 Resistor Setting for Non-standard Socket DevicesThe default pinou

Seite 68 - NetBootLoader VMP1

VMP1 ConfigurationID 26037, Rev. 01 Page 4 - 5® 2002 PEP Modular Computers GmbH4.2 Pinouts4.2.1 Flash Socket Type Selection4.2.1.1 Socket Device Selec

Seite 69 - 5. NetBootLoader

VMP1 ConfigurationID 26037, Rev. 01Page 4 - 6 ® 2002 PEP Modular Computers GmbH4.2.2 Serial Interface Expansion Connector (CON3)Table 4-5: RS Expansio

Seite 70

VMP1 ConfigurationID 26037, Rev. 01 Page 4 - 7® 2002 PEP Modular Computers GmbH4.3 Board Address Map4.3.1 Address Map Overview Figure 4-1: VMP1 Addres

Seite 71 - VMP1 NetBootLoader

VMP1 ConfigurationID 26037, Rev. 01Page 4 - 8 ® 2002 PEP Modular Computers GmbH4.3.2 VME Address Area Figure 4-2: VME Address Area VME bus slave addre

Seite 72

VMP1 ConfigurationID 26037, Rev. 01 Page 4 - 9® 2002 PEP Modular Computers GmbH4.3.3 Onboard Device Addresses Figure 4-3: VMP1 Device Address MapNot

Seite 73

VMP1 ConfigurationID 26037, Rev. 01Page 4 - 10 ® 2002 PEP Modular Computers GmbH4.3.4 Special Registers OverviewThe Special Registers may be attached

Seite 74

VMP1 ConfigurationID 26037, Rev. 01 Page 4 - 11® 2002 PEP Modular Computers GmbH4.3.4.4 Memory Configuration Register• Bits SZ0 and SZ1 are used to id

Seite 75

VMP1 ConfigurationID 26037, Rev. 01Page 4 - 12 ® 2002 PEP Modular Computers GmbH4.3.4.7 Watchdog Control Register4.3.4.8 Watchdog Timeout TimeBits WDT

Seite 76

VMP1 ConfigurationID 26037, Rev. 01 Page 4 - 13® 2002 PEP Modular Computers GmbH4.3.4.9 Control Register• Bits 0 – 1: A “1” written to these bits ligh

Seite 77

Preface VMP1ID 26037, Rev. 01Page 0 - 6 ® 2002 PEP Modular Computers GmbH4.3.4.9 Control Register ...

Seite 78

VMP1 ConfigurationID 26037, Rev. 01Page 4 - 14 ® 2002 PEP Modular Computers GmbH4.3.4.11 Board / Logic Revision Register The Board Revision Register m

Seite 79 - 5.7 Commands

VMP1 ConfigurationID 26037, Rev. 01 Page 4 - 15® 2002 PEP Modular Computers GmbH4.3.4.12 UART A / RegistersFor a detailed description please refer to

Seite 80

VMP1 ConfigurationID 26037, Rev. 01Page 4 - 16 ® 2002 PEP Modular Computers GmbH4.3.4.13 UART B / RegistersFor a detailed description please refer to

Seite 81

VMP1 ConfigurationID 26037, Rev. 01 Page 4 - 17® 2002 PEP Modular Computers GmbH4.3.5 IRQ RoutingTable 4-23: Serial IRQ’sIRQ Name SourceS_IRQ0 Reserve

Seite 82

VMP1 ConfigurationID 26037, Rev. 01Page 4 - 18 ® 2002 PEP Modular Computers GmbH4.3.6 Real-time ClockAccess to the RTC is effected via the I2C bus. Th

Seite 83

VMP1 ConfigurationID 26037, Rev. 01 Page 4 - 19® 2002 PEP Modular Computers GmbH4.3.7 EEPROMAccess to the EEPROM is effected via the I2C bus of the MP

Seite 84

® 2002 PEP Modular Computers GmbHThis page was intentionally left blank.

Seite 85

NetBootLoaderChapter5ID 26037, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5 - 1VMP1 NetBootLoader5.1 General Operation ...

Seite 86

NetBootLoader VMP1Page 5 - 2 © 2002 PEP Modular Computers GmbH ID 26037, Rev. 015.5 Plug and Play ...

Seite 87

VMP1 NetBootLoaderID 26037, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5 - 35. NetBootLoaderThe CPU board is delivered with the NetBootLoader soft

Seite 88

VMP1 PrefaceID 26037, Rev. 01 Page 0 - 7® 2002 PEP Modular Computers GmbH5.6 Porting an Operating System to the CPU Board ...

Seite 89

NetBootLoader VMP1Page 5 - 4 © 2002 PEP Modular Computers GmbH ID 26037, Rev. 015.2.1 ABT (Abort) SwitchThe ABT switch, located on the CPU board front

Seite 90

VMP1 NetBootLoaderID 26037, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5 - 55.3.1 NetBootLoader ControlThe NetBootLoader provides various function

Seite 91

NetBootLoader VMP1Page 5 - 6 © 2002 PEP Modular Computers GmbH ID 26037, Rev. 015.3.3 ftp Server AccessThe NetBootLoader provides various functions fo

Seite 92

VMP1 NetBootLoaderID 26037, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5 - 75.4 Operating the NetBootLoader5.4.1 Initial SetupThe CPU board is del

Seite 93

NetBootLoader VMP1Page 5 - 8 © 2002 PEP Modular Computers GmbH ID 26037, Rev. 015.4.3 NetBootLoader ConfigurationThere are several NetBootLoader comma

Seite 94

VMP1 NetBootLoaderID 26037, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5 - 95.4.3.4 PFThis command is used to set the port parameters for the TERM

Seite 95

NetBootLoader VMP1Page 5 - 10 © 2002 PEP Modular Computers GmbH ID 26037, Rev. 015.4.5.2 Programming an ApplicationThe application image itself must b

Seite 96

VMP1 NetBootLoaderID 26037, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5 - 11The image must start at the absolute address 0x0 and must contain exe

Seite 97

NetBootLoader VMP1Page 5 - 12 © 2002 PEP Modular Computers GmbH ID 26037, Rev. 015.4.7 Uploading a FLASH AreaThe NetBootLoader also has the possibilit

Seite 98

VMP1 NetBootLoaderID 26037, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5 - 135.7 CommandsThe following commands are available with the NetBootLoad

Seite 99 - VMP1-IO1 Module (Optional)

Preface VMP1ID 26037, Rev. 01Page 0 - 8 ® 2002 PEP Modular Computers GmbHFiguresFigure Number and Title2-1 Functional Block Diagram ...

Seite 100 - B Board Interfaces

NetBootLoader VMP1Page 5 - 14 © 2002 PEP Modular Computers GmbH ID 26037, Rev. 01 DESCRIPTION: The option “-f” is used to force updating of the CRC

Seite 101 - C Board Layout

VMP1 NetBootLoaderID 26037, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5 - 15 DESCRIPTION: If an ftp server session has been established with th

Seite 102 - VMP1-IO1

NetBootLoader VMP1Page 5 - 16 © 2002 PEP Modular Computers GmbH ID 26037, Rev. 01SYNTAX:clone [-n]where:clone command-n option:program from data buffe

Seite 103 - E Technical Specifications

VMP1 NetBootLoaderID 26037, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5 - 17 Program NetBootLoader from DIL FLASH (image not valid)COMMAND / RE

Seite 104 - F Board Installation

NetBootLoader VMP1Page 5 - 18 © 2002 PEP Modular Computers GmbH ID 26037, Rev. 01 SYNTAX:help?DESCRIPTION: This command displays the online help pa

Seite 105

VMP1 NetBootLoaderID 26037, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5 - 19SYNTAX:lf [-o[=]<offset> [-k]]… [-m[=]<adr> -l[=]<len&

Seite 106 - GPinouts

NetBootLoader VMP1Page 5 - 20 © 2002 PEP Modular Computers GmbH ID 26037, Rev. 01DESCRIPTION: If no offset option (“-o”) is specified the image is con

Seite 107 - G2 Jn2 (CON5) Pin Assignment

VMP1 NetBootLoaderID 26037, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5 - 21 USAGE:Program FLASH from data buffer to offset 0xF4240 and retain ad

Seite 108 - HJumper Setting

NetBootLoader VMP1Page 5 - 22 © 2002 PEP Modular Computers GmbH ID 26037, Rev. 01 SYNTAX:logoutDESCRIPTION: A remote telnet session will be terminate

Seite 109 - Appendix

VMP1 NetBootLoaderID 26037, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5 - 23 NETFUNCTION: Set or display the parameters for the Ethernet interfa

Seite 110

VMP1 PrefaceID 26037, Rev. 01 Page 0 - 9® 2002 PEP Modular Computers GmbH2.5 Serial Interface Expansion Connector (CON3) Pinout ...

Seite 111 - VMP1-Post (Optional)

NetBootLoader VMP1Page 5 - 24 © 2002 PEP Modular Computers GmbH ID 26037, Rev. 01PASSWDFUNCTION: Set the telnet passwordSYNTAX:passwd [-f | -d]where:p

Seite 112

VMP1 NetBootLoaderID 26037, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5 - 25 PCIFUNCTION: Display PCI informationSYNTAX:pciDESCRIPTION: The comm

Seite 113

NetBootLoader VMP1Page 5 - 26 © 2002 PEP Modular Computers GmbH ID 26037, Rev. 01 DESCRIPTION: To set or display the operational parameters for the a

Seite 114

VMP1 NetBootLoaderID 26037, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5 - 27PINGFUNCTION: Verify operability of the Ethernet interfaceSYNTAX:ping

Seite 115 - (Serial)

NetBootLoader VMP1Page 5 - 28 © 2002 PEP Modular Computers GmbH ID 26037, Rev. 01 PUTFUNCTION: Upload contents of the data buffer to the ftp server.SY

Seite 116

VMP1 NetBootLoaderID 26037, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5 - 29DESCRIPTION: To permit the operator to force a restart of the system,

Seite 117

NetBootLoader VMP1Page 5 - 30 © 2002 PEP Modular Computers GmbH ID 26037, Rev. 01 SLFUNCTION: Download Motorola S-Records to data bufferSYNTAX:sl [-o[

Seite 118

VMP1ID 26037, Rev. 01VMP1-IO1 Module (Optional)Page A - 1® 2002 PEP Modular Computers GmbHVMP1-IO1 Module (Optional)A Overview ...

Seite 119 - JTAG Subsystem

® 2002 PEP Modular Computers GmbHThis page was intentionally left blank.

Seite 120 - VMP1 JTAG Subsystem

VMP1 VMP1-IO1 Module (Optional)ID 26037, Rev. 01 Page A - 3® 2002 PEP Modular Computers GmbHVMP1-IO1 Module (Optional)A OverviewThe PEP VMP1-IO1 modul

Kommentare zu diesen Handbüchern

Keine Kommentare