Processor subsystem System Event Log Troubleshooting Guide for Intel® S5500/S3420 series Server Boards
48 Intel order number G74211-001 Revision 1.0
8.4.3 QPI Fatal and Fatal #2
The system detected a QPI fatal or non-recoverable error. This is a fatal error.
Table 50: QPI Fatal Error Sensor Typical Characteristics
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 74h (OEM Discrete)
[7:6] – 10b = OEM code in Event Data 2
[5:4] – 00b = Unspecified Event Data 3
[3:0] – Event Trigger Offset = Reserved
The QPI Fatal #2 Error is a continuation of QPI Fatal Error.
Table 51: QPI Fatal #2 Error Sensor Typical Characteristics
Kommentare zu diesen Handbüchern