Kontron COMe-bIP6 Bedienungsanleitung Seite 23

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 133
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 22
COMe-bIP6 / Product Specification
3.6 Electrical Specification
3.6.1 Supply Voltage
Following supply voltage is specified at the COM Express® connector:
VCC:
8.5V - 20V
Standby:
5V DC +/- 5%
RTC:
2.5V - 3.47V
- 5V Standby voltage is not mandatory for operation.
- Extended Temperature (E1) variants are validated for 12V supply only
3.6.2 Power Supply Rise Time
» The input voltages shall rise from ≤10% of nominal to within the regulation ranges within 0.1ms to 20ms.
» There must be a smooth and continuous ramp of each DC input voltage from 10% to 90% of its final set-point
following the ATX specification
3.6.3 Supply Voltage Ripple
» Maximum 100 mV peak to peak 0 – 20 MHz
3.6.4 Power Consumption
The maximum Power Consumption of the different COMe-bIP6 variants is 10 - 58W (100% CPU load on all cores; 90°C CPU
temperature). Further information with detailed measurements are available in Application Note KEMAP054 available on
EMD Customer Section. Information there is available after registration.
23
Seitenansicht 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 132 133

Kommentare zu diesen Handbüchern

Keine Kommentare