Table 36: Address: 0x390 - Carrier Control Register (CCR)
BIT 7 6 5 4 3 2 1 0
NAME CNTRL7 reserved CNTRL3 reserved CNTRL1 CNTRL0
ACCESS R/W R R/W R R/W R/W
RESET000000
BITFIELD DESCRIPTION
[7] CNTRL7 Control bit for COM Express IRQ_OUT# line:
0 = line is deasserted (logic level is HIGH-Z)
1 = line is asserted (logic level is LOW)
[3] CNTRL3 Control bit for COM Express SUS_S3# line:
0 = line is deasserted (logic level is HIGH)
1 = line is asserted (logic level is LOW)
[1] CNTRL1 Control bit for COM Express THRMTRIP# line:
0 = line is deasserted (logic level is HIGH)
1 = line is asserted (logic level is LOW)
[0] CNTRL0 Control bit for COM Express CB_RESET# line:
0 = line is deasserted (logic level is HIGH)
1 = line is asserted (logic level is LOW)