Advanced Setup CP305 BIOS
Page 40 ID 1035-8356, Rev. 1.0
P R E L I M I N A R Y
Serial Port Mode
SDO
This function is used to select the baud rate (transmitted bits per second) of the serial port for
console redirection.
Note: This function is only available when the Remote Access function is set to Enabled.
Optimal and Fail-Safe default settings: 115200 8,n,1
Flow Control
SDO
This function is used to select the flow control for console redirection.
Note: This function is only available when the Remote Access function is set to Enabled.
Optimal and Fail-Safe default settings: None
Redirection After BIOS POST
SDO
This function is used to select redirection after BIOS POST.
Note: This function is only available when the Remote Access function is set to Enabled.
Optimal and Fail-Safe default settings: Always
SETTING DESCRIPTION
115200 8,n,1 Use this setting to select 115200 as the baud rate of the serial port.
57600 8,n,1 Use this setting to select 57600 as the baud rate of the serial port.
38400 8,n,1 Use this setting to select 38400 as the baud rate of the serial port.
19200 8,n,1 Use this setting to select 19200 as the baud rate of the serial port.
09600 8,n,1 Use this setting to select 09600 as the baud rate of the serial port.
SETTING DESCRIPTION
None Use this setting to deactivate flow control.
Hardware Use this setting to select the flow control by hardware.
Software Use this setting to select the flow control by software.
SETTING DESCRIPTION
Disabled Use this setting to turn off the redirection after POST.
BootLoader Use this setting to activate the redirection during POST and during BootLoader.
Always Use this setting to specify that the redirection is always active.