Kontron NSW1U IP Network Server Bedienungsanleitung Seite 38

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 110
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 37
NSW1U Network Server—Server Installations and Upgrades
Kontron IP Network Server NSW1U
Product Guide, rev. 1.4 December 2009
38
9. Lift the processor from the socket.
3.3.4.3 Installing the New Processor
Note: Follow the ESD precautions covered in Section 3.3.4.1, “ESD and Processor Handling
Precautions” on page 36.
To install a processor, follow these instructions:
1. Take the processor out of its packaging and remove the protective shipping cover. (“A”)
Caution: The underside of the processor has components that may damage the socket pins if
installed improperly. The processor must align correctly with the socket opening before
installation. Do not drop the processor into the socket!
2. Orient the processor with the socket so that the processor cutouts match the socket notches.
(Figure 22, “A.)
3. Gently place the processor in the socket. (“B”)
Figure 20. Opening the Load Plate
Figure 21. Removing the Processor Protective Cover
A
B
AF000769
A
AF000770
Seitenansicht 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 109 110

Kommentare zu diesen Handbüchern

Keine Kommentare