AT8901/2/3 Management Commands
Page 6 - 9 AT8901/2/3 CLI Reference Manual
Mode Line Config
6.3.5.1 no session-limit
This command sets the maximum number of simultaneous outbound Telnet sessions to
the default value.
Format
no session-limit
Mode Line Config
6.3.6 session-timeout
This command sets the Telnet session timeout value.The timeout value unit of time is
minutes. A value of 0 indicates that a session remains active indefinitely.
Default 0
Format
session-timeout <0-160>
Mode Line Config
6.3.6.1 no session-timeout
This command sets the Telnet session timeout value to the default. The timeout value
unit of time is minutes.
Format
no session-timeout
Mode Line Config
6.3.7 telnetcon maxsessions
This command specifies the maximum number of Telnet connection sessions that can be
established. A value of 0 indicates that no Telnet connection can be established. The
range is 0-5.
Default 5
Format
telnetcon maxsessions <0-5>
Mode Privileged EXEC
6.3.7.1 no telnetcon maxsessions
This command sets the maximum number of Telnet connection sessions that can be
established to the default value.
Format
no telnetcon maxsessions
Mode Privileged EXEC
6.3.8 telnetcon timeout
This command sets the Telnet connection session timeout value, in minutes. A session
is active as long as the session has not been idle for the value set. The time is a decimal
value from 1 to 160.